MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 493.73 HPU Interface Board
Digital I/O and Transition Boards
240
J23 E-Stop Output Connections for the Model 493.73 HPU Interface Board
Connector J23 E-STOP Out provides a set of E-Stop relay contacts that can
be used with external devices. An E-Stop on any of the E-Stop buttons
connected to the chassis will de-energize the E-Stop relay.
Cable specifications To maintain EMC compliance, 23 E-STOP Out cables must comply with
the following specifications:
Connector —9-contact, type D, female EMI connector.
Backshell–EMI metallized plastic or metal.
Cable—AWG and number of conductors as required. Braided shield with
shield connected to the metallized backshell at the chassis.