Mts ReNew Technical Reference Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Mts ReNew Technical Reference. MTS ReNew Technical Reference User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - ReNew Technical Reference

ReNew Technical Referencel100-178-163 A

Strany 2 - Publication information

ReNew Technical Reference10Contacting MTSPrefaceContacting MTSMTS provides a full range of support services after your system is installed. If you hav

Strany 3 - Contents

Contacting MTSReNew Technical Reference Preface11What to Expect When You CallNote Some of the following information specifically discusses what to exp

Strany 4

ReNew Technical Reference12Contacting MTSPrefaceKnow relevant computerinformationIf you are experiencing a computer problem, have the following inform

Strany 5

ReNew Technical Reference Introduction13IntroductionThe ReNew®and ReNew SMA®Upgrade System product series are the latest generation of system upgrade

Strany 6 - About This Manual

ReNew Technical Reference14DescriptionIntroductionDescriptionGeneral description The ReNew products allow the user to utilize the latest control elect

Strany 7 - Conventions

DescriptionReNew Technical Reference Introduction15Controller functions All ReNew systems are controlled by MTS's latest precision frame controll

Strany 8

ReNew Technical Reference16DescriptionIntroductionThe ReNew SMA When a material testing system to be upgraded has a functioning servomotor and amplifi

Strany 9 - Other conventions

SpecificationsReNew Technical Reference Introduction17SpecificationsEnvironmentalspecifications(indoor use only)Individual ReNewmodel specificationsRe

Strany 10 - Contacting MTS

ReNew Technical Reference18SpecificationsIntroductionReNew SMA andReNew SMA-DAPhysicalHeight460 mm (18.1 in)Width180 mm (7.1)Depth432 mm (17.0 mm)Weig

Strany 11 - What to Expect When You Call

ReNew Technical Reference Installation19InstallationLocation andventilationAll ReNew boxes can be placed on the floor next to or behind a floor-standi

Strany 12

Copyright information © 2007 MTS Systems Corporation. All rights reserved.Trademark information MTS and TestWorks are registered trademarks of MTS Sys

Strany 13 - Introduction

ReNew Technical Reference20InstallationAppliance inletconfigurationsThe ReNew Elite has an IEC 60320 C20 appliance inlet. The conductor configuration

Strany 14 - Description

ReNew Technical Reference Installation21External earthconnectionThe ReNew systems have an additional ground connection on the rear of the enclosure. T

Strany 15

ReNew Technical Reference22InstallationThis switch must be located no more than 1 meter from the test space and must be rigidly attached to the machin

Strany 16 - The ReNew

ReNew Technical Reference Installation23ReNew Elite systemconnectionsCable Description MTS #1 CABLE-USB V2.0 CABLE,A-B,3 METER/10 FOOT 100-096-4192 CA

Strany 17 - Specifications

ReNew Technical Reference24InstallationReNew SMA systemconnectionsOn Instron 4400 frames, the control cable (#2 above) plugs into the existing handset

Strany 18 - ReNew SMA-DA

ReNew Technical Reference Installation25For these applications the existing motor, amplifier, controls, and signal conditioning must be functional. Th

Strany 19 - Installation

ReNew Technical Reference26InstallationInstalling cablesExercise care when connecting cables. Ensure that you are using the correct cables and that al

Strany 20 - Appliance inlet

ReNew Technical Reference Installation27J8—DC Conditioner 2. Could be strain based extensometer, second load cell, or high level analog output sensor.

Strany 21 - Connection diagrams

ReNew Technical Reference28InstallationJ2 Handset This is intended to interface to the handset. Specifics for this connector are:• 12 V output power w

Strany 22

ReNew Technical Reference Installation29J3 Interlock This is intended to connect to a test area enclosure switch that opens when the door is opened. I

Strany 23 - ReNew Elite system

ReNew Technical Reference Contents3ContentsPreface 5About This Manual 6Conventions 7Contacting MTS 10What to Expect When You Call 11Int

Strany 24 - ReNew SMA system

ReNew Technical Reference30InstallationJ5 Digital I/O Digital I/O signals include three optically isolated inputs, three optically isolated outputs, a

Strany 25

ReNew Technical Reference Installation31J6 and J7MonitorTwo Monitor connectors are provided. There are several possible uses for analog monitor output

Strany 26 - Installing cables

ReNew Technical Reference32Installation

Strany 27

Handset ControlReNew Technical Reference Operation33OperationHandset ControlThe handset has an encoder and buttons to help you during specimen install

Strany 28

ReNew Technical Reference34Handset ControlOperationHandset functions The handset is intended to be used in a system for specimen loading or setup. In

Strany 29

Handset ControlReNew Technical Reference Operation35Safety Symbols(inside)These symbols are present “inside” the testing system enclosure.Item Descrip

Strany 30

ReNew Technical Reference36Handset ControlOperationTravel limit switches(Physical limits)The manner in which limit switch adjustments are made varies

Strany 31 - Conditioner

Handset ControlReNew Technical Reference Operation37

Strany 32

ReNew Technical Reference38Handset ControlOperation

Strany 33 - Operation

ReNew Technical Reference Maintenance39MaintenanceDisconnect the power cord from the wall outlet before cleaning or lubricating any part of the test f

Strany 34

ReNew Technical Reference4Contents

Strany 35 - (inside)

ReNew Technical Reference40MaintenanceSemiannualmaintenance1. Remove system covers and vacuum or blow out any dust or debris from inside the test fram

Strany 36 - (Physical limits)

ReNew Technical Reference Troubleshooting Guide41Troubleshooting GuideUse this chapter to identify mechanical and electronic problems with your ReNew

Strany 37 - Handset Control

ReNew Technical Reference42Troubleshooting GuideCrosshead will not stop • Servo is improperly connected.• Improper machine parameters. Contact an MTS

Strany 38

Additional Digital I/O InformationReNew Technical Reference Appendix43AppendixAdditional Digital I/O InformationThe digital inputs have an MOCD223 opt

Strany 39 - Maintenance

ReNew Technical Reference44Additional Digital I/O InformationAppendixA typical example might be connecting an external switch.Insight ControllerIN 1-G

Strany 40 - Semiannual

ReNew Technical Reference Configuration Drawings45Configuration DrawingsThe following Insight Renew Board Jumpers & Fuses configuration chart is i

Strany 41 - Troubleshooting Guide

ReNew Technical Reference46Configuration Drawings

Strany 42

Schematic DWG: 700-003-357 Deviations on DesignatorDescription Dwg Sheet Mong - Elite & SMAMong - Alliance ADC - GFCC QFCC This System:X1 Install

Strany 43 - Appendix

100-178-163 MWC Reision A

Strany 45 - Configuration Drawings

ReNew Technical Reference Preface5PrefaceSafety first! Before you attempt to use your MTS product or system, read and understand all safety informatio

Strany 46

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Strany 47

ReNew Technical Reference6About This ManualPrefaceAbout This ManualPurpose This manual provides detailed information about the ReNew™ and SMA Upgrade

Strany 48 - 100-178-163 MWC Reision A

About This ManualReNew Technical Reference Preface7ConventionsThe following sections describe some of the safety conventions that are used in your MTS

Strany 49

ReNew Technical Reference8About This ManualPrefaceWarning notices Warning notices indicate the presence of a hazard which can cause severe personal in

Strany 50

About This ManualReNew Technical Reference Preface9Safety Symbols These symbols are present on the exterior of the testing system.Other conventionsNot

Komentáře k této Příručce

Žádné komentáře