Mts Fracture Analyzer Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Mts Fracture Analyzer. MTS Fracture Analyzer User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 96
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
MTS TestSuite™ Fracture Analyzer User Guide
100-219-118 E be certain.
Zobrazit stránku 0
1 2 3 4 5 6 ... 95 96

Shrnutí obsahu

Strany 1 - 100-219-118 E be certain

MTS TestSuite™ Fracture Analyzer User Guide100-219-118 E be certain.

Strany 2

• Write down any specific instructions.After you callMTS logs and tracks all calls to ensure that you receive assistance for your problem or request.

Strany 3 - Contents

2.0 Preface2.1.0 Before You BeginSafety first!Before you use your MTS product or system, read and understand the safety information provided with your

Strany 4 - 6.0 Data Analysis 53

CAUTION:Caution notices indicate the presence of a hazard with a low level of risk which, ifignored, could cause moderate or minor personal injury or

Strany 5 - 7.0 Variable Analysis 61

Hypertext linksThe electronic document has many hypertext links displayed in a blue font. All blue words in the body text,along with all contents entr

Strany 7 - 1.0 Technical Support

3.0 IntroductionTopics:•Application Overview...

Strany 8

3.1.0 Application OverviewThis application enables standard and custom in-depth analysis of test data, including post-processing, usingbasic statistic

Strany 9

DescriptionIconNameA test is the core component of MTS TestSuite. The test contains the testdefinition along with any test runs, analysis definitions,

Strany 10

A Project Contains Project Settings, Tests, and Test Templates3.2.2.0 TestA Test is stored within a project folder, and contains the following compone

Strany 11 - 2.0 Preface

A Test Contains the Test Definition, Test Run(s), Analysis Definition(s), and Analysis Run(s)3.2.3.0 Test DefinitionThe test definition is stored with

Strany 12

© 2013 MTS Systems Corporation. All rights reserved.Trademark InformationMTS is a registered trademark of MTS Systems Corporation within the United St

Strany 13 - Hypertext links

of the test. After a test run is complete, values that are stored in variables can be changed using theFatigue Analyzer and the Fracture Analyzer in o

Strany 14

Components of a Test RunMTS TestSuite™ Fracture Analyzer User Guide 213.0 Introduction

Strany 15 - 3.0 Introduction

3.2.5.0 Test Run State ColorsThe color of a test run entry indicates its run state.Test Run State ColorsDescriptionColorThe test run completed success

Strany 16 - 3.1.0 Application Overview

An Analysis Definition Contains Views, Displays, Variables, DAQ Mappings, and Functions3.2.7.0 Analysis RunsAnalysis runs apply the views and variable

Strany 17 - 3.2.1.0 Project

Analysis Runs use the Analysis Definition and Test Run Data to Generate Data3.3.0 Viewing the Main WindowThe Fracture Analyzer application main window

Strany 18 - 3.2.2.0 Test

DescriptionCalloutError List Panel3Closes Error List and Message Log4Message Log5Work Area63.4.0 Using the Menu Bar3.4.1.0 File Menu OptionsMenus prov

Strany 19 - 3.2.3.0 Test Definition

DescriptionItem• Test Run—Imports a test run.• Legacy Data—Retrieves test runs, templates or files from data archivedfrom previous software products.

Strany 20 - 3.2.4.0 Test Run

View Menu OptionsDescriptionItemReturns all views to a docked position.Re-Dock All ViewsCloses all views in the work area.Close All ViewsAllows you to

Strany 21 - Components of a Test Run

DescriptionItemShows or removes the Message Log panel. A check mark appears next tothe menu item when the panel is active. To remove or show the panel

Strany 22 - 3.2.6.0 Analysis Definitions

3.5.0 Using the Analysis ToolbarThe Analysis Toolbar allows you to click an icon to create a new chart or table, manage editors, functions,views, and

Strany 23 - 3.2.7.0 Analysis Runs

Contents1.0 Technical Support 71.1.0 How to Get Technical Support...

Strany 24 - 3.3.0 Viewing the Main Window

DescriptionItemUpdate all references to variables, calculation, and data acquisition definitionsusing the current configuration and overridden variabl

Strany 25 - 3.4.0 Using the Menu Bar

4.0 Getting StartedTopics:•Begin an Analysis...

Strany 26 - 3.4.3.0 View Menu Options

4.1.0 Begin an AnalysisYou can begin an analysis using a sample test to help you learn the application. If you have a test createdin a testing applica

Strany 27 - 3.4.4.0 Display Menu Options

4.2.0 Data Analysis4.2.1.0 Activities and TestsAnalysis activities include mathematical and statistical evaluation of the results obtained from the ma

Strany 29

5.0 Customizing the Main WindowTopics:•Overview...

Strany 30

5.1.0 Overview5.1.1.0 Understanding Views and DisplaysWithin the application's main window, data is shown in Charts and Tables. Charts and tables

Strany 31 - 4.0 Getting Started

Four Views Containing Peak-Valley DataWhen you are finished resizing the views to your liking, you can save the current on-screen presentation ofviews

Strany 32 - 4.1.0 Begin an Analysis

5.1.2.0 Creating, Editing, and Deleting ViewsWhen you create a new view, it is stored in the analysis run. If you delete a view, no change is made to

Strany 33 - 4.2.0 Data Analysis

Split-Screen DisplayUndocked displaysWhen an undocked display is closed, only the window size is retained. When a display is reopened on adual-screen

Strany 34

4.2.4.0 Opening an Existing Analysis Run...335.0 Customizing the Main Win

Strany 35

5.2.0 Configuring Chart and Table Properties5.2.1.0 Populating Charts with DataSome charts, such as the Load vs. Time and Hysteresis charts, allow you

Strany 36 - 5.1.0 Overview

DescriptionItemAssign an array to the selected trace that is added on the Y axis. Click thedrop-down button for a list of available resource arrays. W

Strany 37

DescriptionItemSelect the check box to allow a range to automatically expand if the dataexceeds the maximum and minimum ranges. The chart does not res

Strany 38

5.2.6.0 Limit or Curve Fit Line PropertiesLimit or Curve Fit LinesDescriptionItemClick to add a limit or curve fit line.Add a Limit or CurveFit LineCl

Strany 39

5.3.0 Charts and Tables (Views)5.3.1.0 Array-Variable ChartThe Array-Variable chart shows data that is collected and calculated during each test cycle

Strany 40 - 5.2.3.0 Traces Properties

RuntimeIn the Multipurpose Elite application, hysteresis charts are available as part of the Runtime Display andView Results.To create a new Hysteresi

Strany 41

5.3.4.0 History Marker ChartThe History Marker chart allows you to add markers and lines to history charts. In fatigue tests, you can showfailure cycl

Strany 42

DescriptionItemShows a panel to set one variable value. The selected marker value appearsin the New Failure Cycle Chart panel. The Value box is unavai

Strany 43

Cycle Marker Chart PropertiesDescriptionItemSpecify a unique name to identify the chart in the test.Display NameIf more than one type of group is avai

Strany 44 - 5.3.3.0 Hysteresis Chart

DescriptionItemClick this button to show the Numeric Selection window.NumericClick this button to show the Variables Selection window.Variable5.3.8.0

Strany 45

6.3.1.0 Multiple Test Runs Overview...576.3.2.0 Analyze Multiple

Strany 46 - 5.3.4.0 History Marker Chart

5.3.9.0 Variable TableThe Variable table shows the current value of the selected analysis run variables. The table supports directvalue overrides that

Strany 47 - 5.3.6.0 Cycle Marker Chart

Fixed-Column Boundary Table5.3.11.0 Variable-Column Boundary TableThe Variable-Column Boundary table shows the current values of the selected variable

Strany 48 - 5.3.7.0 Cycle Time Chart

5.3.13.0 Variable Table for Multiple RunsThe Variable Table for Multiple Runs shows data from two or more analysis runs selected as a multi-runanalysi

Strany 49 - 5.3.8.0 Array-Variable Table

6.0 Data AnalysisTopics:•Analysis...

Strany 50 - 5.3.9.0 Variable Table

6.1.0 AnalysisThe application supports a variety of analysis activities, including:• Analysis of completed tests• Reanalysis of a data set requiring u

Strany 51

specific table. To use a variable in more than one data acquisition activity table, you must map it for eachtable.8. To select the data acquisition ac

Strany 52

The table row becomes highlighted. The value becomes bold and underlined.Your cursor blinks in thetable cell. A value entry icon appears at the left e

Strany 53 - 6.0 Data Analysis

6. Select the Is Calculated check box and click ...The Calculation Editor window opens.7. In the Variables panel, select Diameter and right-click Ins

Strany 54 - 6.1.0 Analysis

6.3.2.0 Analyze Multiple Test RunsWhen the test runs are in your analysis test, open the analysis set and create an analysis run for each testrun. The

Strany 55 - 6.2.0 Variable Table Analysis

6. Click Update Signal List.7. Click Close to save the changes made in the Data Acquisition Editor.Important:You must click Close before the next step

Strany 56

7.6.3.0 Mapping Additional Variable Calculations...847.6.4.0 Tagged Blocks...

Strany 58

7.0 Variable AnalysisTopics:•Variables and Functions...

Strany 59

7.1.0 Variables and FunctionsYou can analyze test results by reviewing the variables and functions used in the test.You can change thedata presented i

Strany 60

Variables Editor WindowParts of the Variables Editor WindowDescriptionItemNumberProvides menus and quick-access toolbar icons that allow you to perfor

Strany 61 - 7.0 Variable Analysis

DescriptionItemNumberFilters by your selected filter criteria and sorts in ascending or descendingorder. If a filter for a column is currently active,

Strany 62 - 7.2.0 Variables Editor

7.2.3.0 Variable DetailsThe Variable Details panel sets the main properties of the selected variable or variables. New categories aredefined using the

Strany 63

DescriptionItem• Array of Boolean—The variable holds multiple values of the Boolean datatype.• Array of Numbers—The variable holds multiple values of

Strany 64 - 7.2.2.0 Variable Categories

DescriptionItemFatigue or Fracture Analysis applications (for example, when a marker ismoved).This check box must be selected if the calculation conta

Strany 65 - 7.2.4.0 Variable Properties

DescriptionItemIf the value of the variable is not within the range, the application adjusts thevalue to be within the range. If the value of the vari

Strany 66

• If you delete a variable that uses a local choice list, you also delete the choice list.• If you delete a variable that uses a global choice list, o

Strany 67

1.0 Technical Support1.1.0 How to Get Technical SupportStart with your manualsThe manuals supplied by MTS provide most of the information you need to

Strany 68 - 7.2.8.0 Choice Lists

7.3.2.0 Array VariablesArray variables store multiple values of the same data type.You can use array variables in several types ofactivities:• Cycle w

Strany 69 - 7.3.0 Variable Classes

After you create the new variable in either the Multipurpose Elite, Fatigue Analyzer, or Fracture Analyzerapplications, the Properties panel appears.

Strany 70 - 7.3.2.0 Array Variables

7.4.0 Managing Variables7.4.1.0 Variables OverviewYou create and define variables on the Variables tab. The application also provides shortcuts in var

Strany 71 - 7.3.5.0 Calculated Variables

7.4.3.0 Creating a New Variable1. Click the New Variable button.The New Variable window prompts you to type a unique identifier for the new variable.

Strany 72 - 7.4.0 Managing Variables

To locate where the variable is used, click the entry.• For a calculation, the entry for the calculated variable becomes selected.• For an activity, t

Strany 73 - 7.4.5.0 Variable Used By

Note:If adjacent variable names are not separated by a space or function in the Calculation panel, they areinterpreted as a single variable name. This

Strany 74 - 7.5.0 Variable Calculations

Note:Some languages use a semicolon as a list separator instead of a comma. If you are using one of thoselanguages, the last operator of the table wou

Strany 75

DirectionFunctionOperatorPrecedenceLeft-to-RightBitwise OR|10Left-to-RightLogical AND&&11Left-to-RightLogical OR||12Right-to-LeftAssignment=13

Strany 76

However, some operators like the Not (!), Ones Complement (~), and Subtraction when used as a Negate(-), operate on only one argument to the right.Fun

Strany 77 - 7.5.4.0 Calculation Functions

• The function Pi() represents the mathematical constant, pi.• The function SystemRate() represents the system data rate.7.5.6.0 Modulus Calculation F

Strany 78

Know your site number and system numberThe site number contains your company number and identifies your equipment type (such as material testingor sim

Strany 79

Cycle ModulusCycleModulus(Stress, Strain[, startIndexLoading, endIndexLoading, startIndexUnloading,endIndexUnloading])CycleModulus returns the average

Strany 80

StressAStressA(StressMax, StressMin)The StressA function returns the value: ((StressMax - StressMin)/(StressMax + StressMin))StressRStressR(StressMax,

Strany 81 - 7.6.0 Data Acquisition Editor

Data Acquisition Editor WindowDescriptionCalloutAvailable signals1Other available calculations2Additional variables saved with each cycle or group3Map

Strany 82 - 7.6.1.0 Variable Mapping

Signal to Variable MappingThe Signal to Variable Mapping part of the window allows you to map signals to variables.Four types of data can be calculate

Strany 83

• All Variables—Shows all variables, including variables that do not have a calculation.You can changethe variable to include a calculation or change

Strany 84 - 7.6.4.0 Tagged Blocks

an incomplete pattern indicates a group to investigate. Configure the Hysteresis chart to show you the datafor the groups or cycles of interest.You ca

Strany 85

7.7.0 Function Manager OverviewThe Function Manager window provides information about the specialized calculations that are used formaterial testing.

Strany 86

DescriptionItemShow the user-defined type of functions. Functions created in the GeometrySpecimen Editor fall into the Geometry category. Functions cr

Strany 87 - 7.7.1.0 Edit Function

DescriptionItemthe new name shows in this box.The name is case-sensitive, and must notcontain spaces.Shows the function category. If you create the fu

Strany 88

Note:The example above is not entered as TestVariableX=10.You must enter SetValue in the FunctionEditor.ArraysTo read a test variable array in a funct

Strany 89 - 7.7.3.0 Update All

• Keyboard enhancers• Print spoolers• Messaging applications1.3.0 If You Contact MTS by PhoneA Call Center agent registers your call before connecting

Strany 90

geometry-specific calculations. Placeholders for the common functions are added to the test, if any are notalready there.The body of the function is u

Strany 91

1. In the Multipurpose Elite application Explorer tab, click Test Definition and click on the Edit button. Inthe Fatigue Analyzer and Fracture Analyze

Strany 93

IndexAanalysisactivities 33begin 32create definition 22create run 22flow 54runs and sets description 23test run 90without template 32analysis runcompa

Strany 94

Iimporttest file menu option 25invalid cycle values not plotted 46Llimit line 43line and symbolproperties 42Mmain windowFracture Analyzer application

Komentáře k této Příručce

Žádné komentáře