Mts DCPD Measurement System Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Mts DCPD Measurement System. MTS DCPD Measurement System User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - DCPD Measurement System

DCPD Measurement SystemProduct Information100-279-690 B be certain.

Strany 2

Warning:Warning notices indicate the presence of a hazard with a medium level of risk which, if ignored,can result in death, severe personal injury, o

Strany 3 - Table of Contents

Electronic manual conventionsThis manual is available as an electronic document in the Portable Document File (PDF) format. It can beviewed on any com

Strany 5 - Technical Support

SafetyTopics:•General Safety Practices...

Strany 6

General Safety PracticesIf you have system related responsibilities (that is, if you are an operator, service engineer, or maintenanceperson), you sho

Strany 7 - If You Contact MTS by Phone

No User Serviceable Parts WithinPart #572402-07No user serviceable parts within.DCPD Measurement System | 15Safety

Strany 9 - Documentation Conventions

IntroductionTopics:•DCPD Measurement System Introduction...18DCPD

Strany 10 - Caution:

DCPD Measurement System IntroductionThe direct current potential drop (DCPD) crack measurement system is paired with an MTS closed-loopservohydraulic

Strany 11

DescriptionLabelItemCable connector to controller DIO.Control7Power switch: I = on, O = off.I/O8Chassis and earth ground connections.Grounds9Standard

Strany 12

©2014 MTS Systems Corporation. All rights reserved.Original Instructions (English): 100-279-690 BTrademark InformationMTS, be certain., Bionix, Elasto

Strany 13 - DCPD Measurement System

SpecificationsSpecificationParameter100-240VAC, 50-60Hz, 5-2AmpInput voltage5ºC to 40ºC (41ºF to 104ºF)Temperature5% to 85%, non-condensingHumidity200

Strany 14 - Hazard Placard Placement

InstallationTopics:•Installation...

Strany 15 - DCPD Measurement System

InstallationThis chapter explains how to set up and install the hardware for the DCPD Measurement System and TestController, configure the FlexTest so

Strany 16

Caution:There is dangerous voltage inside the enclosure.Connecting cables with power applied can cause damage to the device.Ensure that the power is t

Strany 17 - Introduction

DescriptionItemActive Specimen14Connection to electrical main power5Electrical and earth grounds6Terminal Block71. Connect the remote current control

Strany 18

6. Connect Channel 2.a) Connect the orange cable to the orange Channel 2 connection on the back of the DCPD MeasurementSystem.b) Attach the other end

Strany 19

c) Connect the shield cable to the signal ground connection on the back of the DCPD MeasurementSystem.d) Connect the other ends of the cables to the t

Strany 20

Note:After making changes to the .hwi file, re-run the system loader.3. Configure Station Builder.a) Open Station Builder.If prompted to enter a passw

Strany 21 - Installation

1. For Display Units, select "V" for Volts.6. Assign and configure the DUC for DCPD Channel 2.a) In the left navigation pane, go to Auxiliar

Strany 22 - Connect the Cables

If prompted to enter a password, use the appropriate password.The Open Configuration window will open.b) Open the test config. file that was configure

Strany 23

Table of ContentsTechnical SupportHow to Get Technical Support...

Strany 24

Station Builder: Current CommandDigital Outputs OffManual Command- Digital Output On, Reverse Off30 | DCPD Measurement SystemInstallation

Strany 25

Manual Command- Digital Output On, Reverse OnChange Gain in DUCActive and Reference Channel- Typical VoltagesDCPD Measurement System | 31Installation

Strany 26 - Set Up the Controller

Digital Output On Reverse OffACT pd and REF pd show measured voltages from the DCPD unit. These are typical starting values.Current Output shown is ha

Strany 27

Foil SpecimenAfter the DCPD Measurement System is installed and the Controller is setup, the foil specimens is usedto verify the DCPD unit is function

Strany 28

The following sequence is a guideline for using the foil specimen in validation system operation. Thesequence assumes the DCPD unit has been connected

Strany 29

OperationTopics:•Operation...

Strany 30 - 30

OperationOperation during testing is primarily controlled through software and the Test Controller. Refer to yoursoftware and controller documentation

Strany 31 - DCPD Measurement System

You should choose settings that provide the best feedback signal for a majority of your signals. It mightbe necessary to use a smaller gain or current

Strany 33 - Foil Specimen

MaintenanceTopics:•Maintenance...

Strany 34

4Table of Contents

Strany 35 - Operation

MaintenanceMaintenance of the DCPD consists of keeping the unit clean and occasionally cleaning the filter.The unit can be wiped off with a clean, dam

Strany 36

TroubleshootingTopics:•Troubleshooting...

Strany 37

TroubleshootingSolutionProblemVerify the power switch is on (I/0 switch on the back panel to I). Verifyany main power circuit breaker is on. Verify th

Strany 38

SolutionProblem3) Verify that the gains in the controller for the appropriate signal arenot zero.4) Verify the continuity of the cable is good, by tes

Strany 41 - Troubleshooting

MTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within U.S. or Canada)Phone:952-937-4

Strany 42

Technical SupportHow to Get Technical SupportStart with your manualsThe manuals supplied by MTS provide most of the information you need to use and ma

Strany 43

When you have more than one MTS system, the system job number identifies your system. You can findyour job number in your order paperwork.Example syst

Strany 44

— Messaging applicationsIf You Contact MTS by PhoneA Call Center agent registers your call before connecting you with a technical support specialist.

Strany 45

• Record the name of the person who helped you.• Write down any specific instructions.After you callMTS logs and tracks all calls to ensure that you r

Strany 46

PrefaceBefore You BeginSafety first!Before you use your MTS product or system, read and understand the safety information provided withyour system. Im